acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Backup Lamp Relay|Locations|Page 287 > < Backup Lamp Relay|Locations|Page 285
Page 1
background image

Backup Lamp Relay: Testing and Inspection

Power Relay Test

Normally-open type A:

Check for continuity between the terminals.

-

There should be continuity between the No. 1 and No. 2 terminals when power and ground are connected to the No. 3 and No. 4 terminals.