Shift Interlock Relay: Testing and Inspection

Five-terminal type B:

Check for continuity between the terminals.

-

There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.

-

There should be continuity between the No.1 and No.4 terminals when power is disconnected.