Integra L4-1797cc 1.8L DOHC (VTEC) (1996)
4. Loosen the locknut and turn the adjusting screw until feeler gauge slides back and forth with a slight amount of drag.
5. Tighten the locknut and recheck clearance again. Repeat adjustment if necessary.
6. Rotate the crankshaft 180° counterclockwise (camshaft pulley turns 90°). The "UP" mark should be on the exhaust side.
Adjust valves on No.3 cylinder.