Integra L4-1797cc 1.8L DOHC (VTEC) (1996)
PGM-FI Main Relay: Testing and Inspection
Relay Testing
NOTE:
-
If the car starts and continues to run, the PGM-FI main relay is OK.
1. Remove the PGM-FI main relay.
2. Attach the battery positive terminal to the No. 2 terminal and the battery negative terminal to the No. 1 terminal of the PGM-FI main relay. Then
check for continuity between the No. 5 terminal and No. 4 terminal of the PGM-FI main relay.
-
If there is continuity, go on to step 3.
-
If there is no continuity, replace the PGM-FI main relay and retest.
3. Attach the battery positive terminal to the No. 5 terminal and the battery negative terminal to the No. 3 terminal of the PGM-FI main relay. Then
check that there is continuity between the No. 7 terminal and No. 6terminal of the PGM-FI main relay.
-
If there is continuity, go on to step 4.
-
If there is no continuity, replace the PGM-FI main relay and retest.
4. Attach the battery positive terminal to the No. 6 terminal and the battery negative terminal to the No. 1 terminal of the PGM-FI main relay. Then
check that there is continuity between the No. 5 terminal and No. 4 terminal of the PGM-FI main relay.
-
If there is continuity, the PGM-FI main relay is OK.
-
If the fuel pump still does not work, go to Harness Testing.
-
If there is no continuity, replace the PGM-FI main relay and retest.
Troubleshooting