13. Turn the water valve off and turn off the water supply.
14. Turn the air valve on to dry the system out with air for two full minutes or until no moisture is visible leaving the drain hose.
CAUTION: Residual moisture in the ATF cooler or pipes can damage the transmission.
15. Remove the flusher from the cooler line. Attach the drain hose to a fluid container.
16. Install the transmission and leave the drain hose attached to the cooler line.
17. Make sure the transmission is in P position. Fill the transmission with ATF, and run the engine for 30 seconds or until approximately one quart is
discharged.
18. Remove the drain hose, and reconnect the cooler return hose to the transmission.