Condenser Fan Motor Relay: Testing and Inspection

RELAY TEST

Normally-Open Type
1. Remove the power relay from its socket.

2. Check continuity between relay terminals.

-

There should be continuity between the A and C terminals when power and ground are connected to the B and D terminals.

-

There should be no continuity when power is disconnected.

-