Integra GS-R Sedan L4-1797cc 1.8L DOHC (VTEC) MFI (1999)
Mode Control Motor (3 Of 3)
Mode Control Motor / Troubleshooting
Mode Control Motor / Test
1. Connect battery power to the No. 4 terminal of the mode control motor and connect ground to the No. 8 terminal.
2. Using a jumper wire, connect the No. 8 terminal individually to the No. 1, 2, 3, 6 and 7 terminals, in that order. Each time the short circuit is made,
the mode control motor should run smoothly and stop.
NOTE: If the mode control motor does not run when shorting the first terminal, short that terminal again after shorting the other terminals.
The mode control motor is OK if it runs when jumping the first terminal again.
3. If the mode control motor does not run in step 2, remove it, and check the mode control linkage and doors for smooth movement. If the mode
control linkage and doors move smoothly, replace the mode control motor.