MDX V6-3471cc 3.5L (2002)
Sunroof / Moonroof Relay: Testing and Inspection
Five-terminal type:
Check for continuity between the terminals.
-
There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.
-
There should be continuity between the No.1 and No.4 terminals when power is disconnected.
Moonroof open relay
Moonroof close relay