100 Wagon L5-2309cc 2.3L SOHC (NF) (1989)
-
tighten bolt 1, 2 and 3 20 N-m (15 ft.lb.)
-
tighten bolts 4 and 5 35 N-m (26 ft.lb.)
NEW Alternator V-Belt Break In ("Run In") Procedure
-
start the engine and run at idle
-
turn on all electrical consumers i.e.: Air Conditioning rear window defogger; head lamps high beam; seat heaters ...
-
let engine idle for at least 20 min.
Note
V-belt will stretch during this "Run In" period.
Caution
Vehicle should not be left unattended or unmonitored during V-belt break in idling period
-
readjust V-belt tension as described above.
Note
In extreme high alternator load conditions (i.e. when many electrical consumers are used such as air conditioning ... ) it may be necessary to inspect and
adjust V-belt 300 - 500 miles after initial installation.
If problems still persist call the
Helpline at:
1-800-388-2834