audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Understanding Track Style Wiring Diagrams, Important Stuff !|Page 3119 > < Understanding Track Style Wiring Diagrams, Important Stuff !|Page 3117
Page 2
background image

Checking Differential Pressure Regulator Current

 

4.

Connect DVM to adapter, set mode to DC milliamps 200mA scale.

 

5.

Start engine and run at 2,000 rpm for 1 minute, then let idle.

 

6.

Check oxygen sensor output voltage.

-

 Voltage should be varying between 300-600 millivolts (0.3-0.6 volts).

7.

Observe differential pressure regulator current.

-

Current should vary between 0 and +5 mA. If not, check basic air/fuel ratio adjustment. See: Fuel Delivery and Air Induction/Idle
Speed/Adjustments If current is more than +5 mA, basic adjustment is too lean. If current is negative in polarity, basic adjustment is too rich.

 

8.

Impose a lean condition by creating a small vacuum leak (unplug a vacuum hose) and observe regulator current and oxygen sensor voltage.

-

Oxygen sensor voltage should immediately drop (for a moment) and then return to the normal range as the computer compensates for the
imposed lean condition. At the same time as the oxygen sensor voltage returns to normal, the pressure regulator current should increase and
continue varying by approximately 5 mA, but at a slightly higher value (i.e. current varies between +5 and +10 mA).

 
    If the voltage and current readings respond as described, the oxygen sensor and the mixture control functions of the computer are operating normally.
If the regulator current is fixed or becomes fixed during testing, run engine at 2,000 rpm for 1 minute to heat sensor up to operating temperature
(300~C/575~F minimum) and re-check. If no voltage reading is obtained from oxygen sensor, replace sensor. If oxygen sensor voltage rises to 0.9-1.0
volts and remains fixed at this voltage, either the engine is running extremely rich (too rich for the computer to compensate), or the oxygen sensor is
contaminated and the engine is actually running lean in response to the false rich indication from the sensor. In either case the computer will be sending a
"full lean command" to the differential pressure regulator (regulator current will be negative and fixed at its lean limit), and the oxygen sensor should be
replaced. If a new sensor's output voltage rises to 0.9-1.0 volts and remains fixed at this point, the engine is running too rich and the rich condition must
be corrected or the new sensor may become contaminated with carbon and rendered inoperative.
 

Understanding Track Style Wiring Diagrams, Important Stuff !|Page 3119 > < Understanding Track Style Wiring Diagrams, Important Stuff !|Page 3117