audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor - Contamination|Page 2549 > < Oxygen Sensor - Contamination|Page 2547
Page 3
background image

^

Specified value: max. 1 (ohm) 

-

Check for continuity between H02S 2 -G108- signal wire and test box socket 48.
^

Specified value: max. 1 (ohm) 

If specified values are not obtained:

-

Repair open or short circuit in wiring connection between connector in engine compartment and terminal 50 and/or 48 of ECM connector A
according to wiring diagrams.

If there is no malfunction in wiring connection:

-

Replace ECM.