audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor - Contamination|Page 844 > < Oxygen Sensor - Contamination|Page 842
Page 2
background image

2-Pin Connector

-

Connect multimeter (Fluke 83 or equivalent) between connector terminals 1, Ground (GND), and 2, positive (8+).

-

Start engine and let idle.
^

Specified value: approx. 12-14 volts  

If specified values are not obtained:

-

Check HO2S circuit breaker -S73- (brown holder in electronics box, passenger side footwell).

-

Check continuity in wiring from connector terminal 2 to circuit breaker using wiring diagram.
^

Specified reading: maximum 0.5 ohms 

-

Check continuity in wiring from connector terminal 1 to GND.
^

Specified reading: maximum 0.5 ohms 

-

Check fuel pump relay.

If the specified reading is obtained:

-

Connect additional test harness VAG 1315 A/1 into 2-pin HO2S connector.
This series connection allows actual current flow measurement

-

Switch multimeter to 10 amp (DC) measuring range and connect (connect test harness to 10 amp connector).

-

Run engine.
^

Specified reading: 0.5-3.0 amps (Current decreases as sensor temperature increases).

If specified reading is not obtained:

-

Replace oxygen sensor.

Checking Oxygen Sensor control

-

Disconnect harness connector for oxygen sensor signal wire.

1C - Right bank
4A - Left bank

-

Connect multimeter between oxygen sensor signal wire and GND.
^

Specified value: infinite ohms  (no continuity) 

If specified values are not obtained:

-

Replace HO2S.

If specified value is obtained:

-

Switch multimeter to 2.0 volt measuring range and connect between signal wire connector of wiring harness to ECM and GND.

-

Switch ignition on.
^

Specified value: 400 +/- 50 mV

If specified values are not obtained, check wiring to ECM:

-

Switch ignition OFF.

-

Connect VAG 1598 test box on ECM wiring harness using VAG 1598/11 adapter harness. See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/Scan Tool Connecting and Initial
Checks/Connecting and Testing VAG 1598 Pin Out Box
^

Adapter harness for ECM is not connected.

-

Check for continuity between H02S -G39- signal wire and test box socket 50.

Oxygen Sensor - Contamination|Page 844 > < Oxygen Sensor - Contamination|Page 842