High Pressure Sensor / Switch: Service and Repair

Function

Switches A/C compressor clutch OFF if system pressure is too high.

-

Switch opens (compressor OFF): 28.2 - 31.0 bar (409 - 449 psi).

-

Switch closes (compressor ON): 10.3 - 17.3 bar (149 - 251 psi).

-

Switch identified by red housing, located on left side of condenser.

Removing And Installing

-

Remove electrical connector and remove high pressure switch. Refrigerant system remains closed (valve under switch).

-

Install new O-ring -A- (9.3 mm x 1.8 mm). Tightening torque: 5 Nm (44 in lb).

NOTE:  Only use O-rings specified for use with R-12 refrigerant and refrigerant oil.

-

DO NOT reuse O-rings, always replace.

-

Lubricate O-rings with A/C refrigerant oil before installing

-

Always use correct size O-ring.

-

During installation, ensure proper seat in groove.

-

Keep work area, components and O-rings clean.