Malfunction Indicator Lamp: Service and Repair

Diagnostic Connectors - Activating Self Diagnostics

1.

With ignition turned "off", connect jumper wire to test connectors as shown in illustration.

2.

Turn ignition "on", wait at least 4 seconds then remove fuse (or jumper wire). The first output check should now be initiated. 

 

3.

Re-insert fuse into relay (or reconnect jumper wire) for 4 seconds then remove. Repeat this step until you have stepped through the output checks
and code 0000 is displayed.

 

4.

Re-insert fuse into relay (or re-connect jumper wire). Wait a few minutes then remove (Audi says to wait 10 seconds, however, it has been
reported that this does not always do the trick, waiting several minutes will). Permanent memory should now be cleared.

 

5.

Re-check fault code memory display to verify that memory has been cleared. If memory did not clear, try again only wait a little longer before
removing fuse from top of relay in step 4 of this procedure.