4000S Diesel L4-1588cc 1.6L DSL SOHC (JK) (1983)
Battery: Technical Service Bulletins
Recharging Maintenance - Free Batteries In Stock
Applies To
All
Group
27
Subject
Key Points
Number
Maintenance-free batteries
Recharging maintenance-free batteries in stock
85-27-01
Part Identifier 2706
(Supersedes Product Circular, Group 27, 84-01)
C August 8, 1985
Check voltage of maintenance-free batteries in stock with a digital voltmeter, on a routine basis every eight (8) weeks.
If battery voltage is below 12.4 V (75% charged), recharge battery to full capacity.
After charging battery and before measuring voltage, remove surface charge by applying a 15 amp load for
15 seconds.
To prevent storage related problems, batteries in stock longest should be sold first.