background image

Radiator Cooling Fan Motor Relay: Customer Interest
Radiator Fan - Stays On

19-89-T01
Jul 89

80/90
All M.Y. 1988-89

100/200
All M.Y. 1989

5000 All
4000 All
M.Y. 1984-88

Radiator Fan - Stays On

Cause:
Fan relay stuck in "On" position. Points welded together.

Production:
Improved positioning and retention of coil windings in relay.

As of:

December 1988

VIN:

44_KN043678

January 1989

VIN:

89_KA155371

Service:
Use only 40 Amp or 70 Amp relays with production code 1/89 or later.

-

40 Amp Relay, Second Stage P/N-443 951 253K

-

70 Amp Relay, Third Stage P/N 443 951 253J

Only latest version relays supplied by Parts Department.