audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Filter > < Intake Preheat|Page 1339
Page 1
background image

Air Cleaner Housing: Adjustments

THERMOSTAT, ADJUSTING

-

install thermostat 1 into adapter 2 with 3 turns

-

install adapter into control box 3

-

immerse thermostat for 2 minutes in luke warm water 20°C / 68°F 

-

turn thermostat further in until control flap shuts off cold air flow

-

lock thermostat in control box with locking compound

CONTROL BOX, INSTALLING

-

install control box in air filter cover so rib A on control box is in line with groove 8 on air filter cover