5000CD Turbo (Canada) L5-2144cc 2.14L SOHC Turbo (KH) (1984)
Hall Effect Sensor: Testing and Inspection
Hall sending unit, checking
Note: Ignition coil wire from distributor must always be grounded with jumper wire when checking Hall sending unit.
Work sequence
-
Remove protective cover from Hall sending unit connector on ignition distributor and unplug connector from unit (arrow)
-
Connect voltmeter to terminals 1 and 3 of connector D
-
Switch ignition ON
^
specifications: minimum 9 V
If specifications NOT OK
-
Check for open circuit in wiring to Hall sending unit according to current flow diagram
If specification OK
-
Switch ignition OFF
-
Nove back protective cover on Hall sending unit connector
-
Connect voltmeter across wires for terminals 1 and 2
Plug connector back into Hall sending unit on distributor
-
Switch ignition ON
-
Remove distributor cap, rotor and dust cover
Note: Distributor cap retaining clips must not interfere with Hall sending unit during test.