5000CD Turbo (Canada) L5-2144cc 2.14L SOHC Turbo (KH) (1984)
Service Solution:
Replace steel pipe from pump to outside fitting (see illustration) with damper unit, P/N 443 422 2 51 B.
NOTE:
1. When working on hydraulic pump, pump and hose must be primed with hydraulic oil, G 022,000.
2.
Whenever a component has disintegrated, all lines must be flushed with hydraulic oil to remove any contaminants that may damage new
components.