audi Workshop Repair Guides

Audi 5000CS Turbo Workshop Service & Repair Manuals

Frequency Valve, CIS Fuel Injection|Locations|Page 2813 > < Frequency Valve, CIS Fuel Injection|Locations
Page 1
background image

Frequency Valve: Testing and Inspection

OXS Frequency valve, checking

Work sequence

Unplug electrical connector (arrow) from OXS frequency valve

Note:  Oxygen sensor frequency valve is located in the passenger side front fender cavity.

-

Using LED test light US 1115, connect red test lead to terminal 1 and black lead to terminal 2 of open OXS frequency valve connector

-

Initiate output diagnosis sequence until code 4441 for OXS frequency valve is displayed
^

Specification: LED on US 1115 must be OFF

If light is OFF

-

Replace OXS frequency valve

If light is ON

-

Connect voltmeter between terminal 1 and ground
^

Specification: approx. 12 V 

If voltage reading NOT OK

-

Check for open circuit in wiring according to current flow diagram

If voltage reading OK

-

Remove control unit cover, located in front passenger footwell

Frequency Valve, CIS Fuel Injection|Locations|Page 2813 > < Frequency Valve, CIS Fuel Injection|Locations