audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Idle Up Control Valve|CIS-E|Page 2697 > < Idle Up Control Valve|CIS-E|Page 2695
Page 1
background image

Idle Up Control Valve: Testing and Inspection

CONTINUITY, CHECKING

-

connect ohmmeter between terminal 1 of the test connection and terminal 15 of the central connector
^

with idle stabilizer valve disconnected

^

specification: zero OHMS (continuity)

-

connect ohmmeter to terminal 2 of the test connection and terminal 3 of the central connector 
^

with idle stabilizer valve disconnected

^

specification: zero OHMS(continuity)

If specification NOT OK

-

check for open circuit, using current flow diagram

VOLTAGE SUPPLY, CHECKING

-

disconnect idle stabilizer valve wiring

-

connect voltmeter between terminal 2 of idle stabilizer valve connector and ground cable

-

switch ON ignition
^

specification: approximately battery voltage

-

switch OFF ignition

-

connect ohmmeter between terminal 3 of the idle stabilizer valve connector and terminal 3 of the disconnected terminal of the KE - control unit 
^

specification: zero OHMS (continuity)

-

connect ohmmeter between terminal 1 of the idle stabilizer valve connector and terminal 4 of the disconnected terminal of the KE - control unit 

-

specification: zero OHMS (continuity)

If specifications NOT OK

-

check for open circuit, using current flow diagram

-

reconnect idle stabilizer valve connector

-

connect ohmmeter between terminal 3 and 4 of the disconnected terminal of the KE - control unit
^

specification: 24 - 30 OHMS

If specification NOT obtained

-

replace idle stabilization valve.

Idle Up Control Valve|CIS-E|Page 2697 > < Idle Up Control Valve|CIS-E|Page 2695