Air/Fuel Mixture > < NHTSA87V170000|Page 3031
Page 4
background image

If current NOT OK

-

check altitude sensor

If current OK

-

reconnect oxygen sensor

-

recheck duty cycle

-

duty cycle must remain within checking value of 28 ± 2% 

-

read current displayed on meter US 1119

-

displayed current must fluctuate

If current DOES NOT fluctuate

-

Check oxygen sensor

If current fluctuates

-

turn ignition OFF

-

reconnect crankcase ventilation and charcoal cannister hoses

-

drive in new plug flush with mixture control unit

-

remove CO meter and reattach cap to CO probe receptacle