5000S Turbo L5-2144cc 2.14L SOHC Turbo (KH) (1984)
Calibration Screw
Note
Range reading calibration (2) can be adjusted by turning only 3/4 turn between stops.
-
turn calibration screw (2) with screw driver
^
specified value: in km approx. 750 in mi approx. 465
If specified value cannot be attained, - check fuel gauge
-
repeat range reading calibration
If specified value still cannot be attained, - replace computer control unit.
FUEL CONSUMPTION DISPLAY (0 MPG), CORRECTING 5000S TURBO USA
Fuel consumption display (MPG), correcting 5000S Turbo USA
Note
If actual fuel consumption deviates more than 10% from fuel consumption calculated by computer, a correction of +/- 15% can be made.
Correct fuel consumption reading by installing permanent jumper wire from a power source to terminals 20 and/or 21 on computer control unit
connector.
Correction range
^
contact 21 +/- 5%
^
contact 20 +/- 10%
Work sequence
-
remove computer control unit
-
connect jumper wires to connector according to chart