5000S Turbo L5-2144cc 2.14L SOHC Turbo (KH) (1984)
-
Use ohmmeter to check continuity between terminals of Hall sender connector D and control unit connector A
^
Connector D terminal (1) and control unit connector A terminal (4)
^
Connector D terminal (2) and control unit connector A terminal (27)
^
Connector D terminal (3) and control unit connector A terminal (25)
^
Each specification: approx. 0 ohm
If NOT OK
-
Check for open circuit in wiring between connectors A and D according to current flow diagram
If wiring OK
-
Replace Hall control unit