audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

By Symptom for Power and Ground Distribution:|979502|Page 846 > < All Technical Service Bulletins for Power and Ground Distribution:|979502|Page 840
Page 1
background image

Power and Ground Distribution: By Symptom
Stabilant 22A - Electrical Contact Enhancer

Group: 97

Number: 9502

Date: Mar. 22, 1995

Subject: 
Electrical Contact Enhancer (Stabilant 22A)

Model(s): 
All All m.y.

Supersedes T.B. 97-94-01 dated Oct. 1, 1994

Note:

T.B. supersession has been written in response to Dealer requests for reimbursement of Stabilant 22A.

Condition

Poor or intermittent electrical contact between an electrical component and its harness connector terminals, can cause customer complaints and may
result in unnecessary replacement of the components.

Service

During the process of diagnosing a customer complaint and before replacing any electrical component always:

-

Inspect and clean the electrical contacts between the harness and the component.

-

Apply electrical contact enhancer Stabilant 22A (see note) to the connector terminals.

Part Number: ZVW 186 001

Caution

Always check with parts department for the latest parts information.

DO NOT apply Stabilant 22A to Oxygen Sensor terminals.

-

Check component function again. If the component functions normally:

-

Complete the diagnosis procedure to assure the customer complaint is resolved.

If component still does not function:

-

Continue diagnosis procedures until problem is found.

For repairs that do not require replacement of a component:

-

Input warranty claims using the electrical harness part identifier. Do not code claims against the component part identifier.

Stabilant 22A reimbursement

To compensate for expense of Stabilant 22A, add labor operation 97A1000 5 T.U. to your warranty claim.

Note

^

Stabilant 22A enhances conductivity, and should be applied to the connector terminals whenever a harness is disconnected as well as when
replacing a component or connector.

^

When applied to electrical connections, Stabilant 22A becomes a conductor and provides the reliability of a soldered connection, without actually
bonding the contacting surfaces together.

^

When applied to multiple pin connectors, Stabilant 22A enhances conductivity between connector terminals while remaining a non-conductor

By Symptom for Power and Ground Distribution:|979502|Page 846 > < All Technical Service Bulletins for Power and Ground Distribution:|979502|Page 840