Fig. 10  Special Tool 1348/1 Installation

3.

Connect test harness (VW 1501) Fig. 8, between the potentiometer and the injection harness plug.

4.

Connect a voltmeter to terminals 2 and 3 on the test harness.

5.

Install tool VW 1348/1, Fig. 10, as follows:

a. Pull the slide out to its upper stop.
b. Set the tool over the center of the sensor opening so that the pointer is towards the fuel distributor.
c. Push the slide down to the stop, then turn the center screw in until the magnet contacts the sensor plate mounting bolt.

6.

Adjust the center screw of the sensor plate positioning tool until the output voltage is the same as it was in the testing procedure. See U2 Output
voltage under Air Flow Sensor Plate Position Sensor. See: Testing and Inspection

7.

Connect the voltmeter between terminals 1 and 3 of the test harness.

Fig. 16  Air Flow Meter Potentiometer Voltage Value Graph

8.

Adjust the potentiometer trim screw until voltage reading is within specification, Fig. 16.

9.

If the voltage values cannot be adjusted to specification, remove the fuel distributor, and air filter housing, then replace the air flow sensor housing
assembly.  The potentiometer cannot be replaced separately.