Engine Control Module: Pinout Values and Diagnostic Parameters
Ohms Measurements

35 Position ECU Plug

For Terminal ID please refer to "Powertrain Management : Computers and Control Systems : Engine Control Module : Connector Views".  See:
Diagrams/Connector Views

CAUTION: When measuring Ohms disconnect the ECU from the harness plug and never turn the ignition key on.  It is possible that failure to follow

these steps will result in damage to the ECU.

GROUNDS

KEY OFF

Pin 18 to G1 .........................................................................................................................................................................................  CONTINUITY
Pin 18 to 34 (M/T only) .......................................................................................................................................................................  CONTINUITY
Pin 18 to 35 .........................................................................................................................................................................................  CONTINUITY
Pin 8 to 18 ...........................................................................................................................................................................................  CONTINUITY

Connect the computer for this reading only.
It is the shield for the 02 sensor and is an output from the computer.

COOLANT TEMPERATURE SENSOR

Pin 3 to 18

68°F ...............................................................................................................................................................................................  2200 - 2700 Ohms
176-194°F ..........................................................................................................................................................................................  150 - 300 Ohms

THROTTLE SWITCH

Pin 14 to 28 (Closed) .................................................................................................................................................................................  CONTINUITY
Pin 14 to 31 (Full load) ..............................................................................................................................................................................  CONTINUITY

ALTITUDE SENSOR

Changes with Altitude

Pin 24 to 26 ....................................................................................................................................................................................  2100 - 2600 Ohms
Pin 24 to 25 ......................................................................................................................................................................................  200 - 3800 Ohms

COLD START INJECTOR

Winding

Pin 14 to 16 ..............................................................................................................................................................................................  8 - 13 Ohms

ELECTRO-HYDRAULIC ACTUATOR

Winding(s)

Pin 4 to 5 ................................................................................................................................................................................................  17 - 22 Ohms

AIR FLOW SENSOR

Disconnect Altitude sensor before taking measurements.
At rest

Pin 24 to 26 (Ref.) ..........................................................................................................................................................................  3300 - 3700 ohms
Pin 24 to 23 (load) .........................................................................................................................................................................  1000 - 1300 Ohms

Flap on air flow sensor closed or air flow senor plate at rest position. Resistance increases as flap or plate opens.

Pin 24 to 23 (load) .........................................................................................................................................................................  4300 - 5000 Ohms

Flap on air flow sensor opened to maximum or air flow plate deflected to maximum.

CARBON CANISTER VALVE

Winding(s)

Pin 14 to 15 ............................................................................................................................................................................................  30 - 60 Ohms

ISC VALVE