audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Throttle Full Close Switch > < Oxygen Sensor Heating|Page 765
Page 1
background image

Oxygen Sensor: Service and Repair

NOTE:  The oxygen sensor replacement interval is 60,000 miles. An OXS mileage counter is not used.

-

disconnect oxygen sensor lead (1)

-

disconnect oxygen sensor heater connector (2) from harness connector (3)

-

unscrew oxygen sensor (arrow) from exhaust Oust ahead of catalyst)

-

installation is reverse of removal procedure

CAUTION:  oxygen sensor threads must be coated with Anti-seize compound before installing. If the sensor has not already been coated in production,
carefully apply a coating to the threads taking extreme care not to allow Anti-seize into the sensor slots.