Temperature Gauge: Diagnostic Aids
Checking Ground Connections

 
Checking ground connections as shown confirms that the circuit is complete-that the necessary path to ground is uninterrupted and current can flow in
the circuit. The example illustrates troubleshooting the high-speed circuit for the radiator cooling fan.

Voltage: If the test light or multimeter indicates voltage, then there is potential for current flow between the known voltage source and ground at
the test point. The ground side of the circuit, between terminal 3 of the fan connector and battery negative (-), is OK.

NO Voltage: The test point is not providing a path that completes the circuit to ground. The fan is probably OK. Look for a fault somewhere in
the wiring between the fan connector and chassis ground. Also check the mechanical ground connection at the chassis (body).