audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Basic Electricity|Page 11200 > < Basic Electricity|Page 11198
Page 2
background image

Audi Special Tools include adapters for making test connections safely and preventing connector damage.  See: Tools and Equipment

Using an LED Test Light or Voltmeter (Multi meter)
Step 1 -
 Remove the fuse
Step 2 - Disconnect the load (powered components) to eliminate the circuit's normal path to ground

Voltage: If the test light or multi meter indicates voltage, then there is a complete circuit-a connection to ground even though all the circuit's
Normal ground paths are eliminated. There is a short-an unintentional connection to ground-somewhere in the circuit.

NO Voltage: There is not a complete circuit. The circuit's normal ground paths have been disconnected, and there is no other connection between
the isolated circuit and ground-no short has been detected.

CAUTION:  Direct contact with meter probes at the connector terminals can easily damage the small contacts, causing poor connections and
risking future intermittent faults.

Audi Special Tools include adapters for making test connections safely and preventing connector damage. See: Tools and Equipment

Basic Electricity|Page 11200 > < Basic Electricity|Page 11198