audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Instrument Panel Voltage Regulator|Testing and Inspection|Page 5110 > < VDO Instrument Cluster|Page 5106
Page 1
background image

Instrument Panel Voltage Regulator: Testing and Inspection

Voltage stabilizer, checking 

Removing and installing voltage stabilizer.   See: Service and Repair

 
 
Checking 

Remove instrument cluster, leaving all instrument cluster connectors attached.   See: Service and Repair

Leave battery Ground (GND) strap connected.

Set digital multimeter (Fluke 83 or equivalent) to voltage measuring range.

Connect red multimeter test lead to terminal -3- (B+).

Connect black multimeter test lead to terminal -2- (GND).

Switch ignition on.
Specification: approx. Battery Positive Voltage (B+) 

If specification is not met:

Check wiring for open circuit according to wiring diagram, and repair as necessary.

Connect red multimeter test lead to terminal -1-.

Connect black multimeter test lead to terminal -2- (GND).

Switch ignition on.
Specification: 9.8-10.4 volts

If specification is not met:

Replace voltage stabilizer.   See: Service and Repair

Instrument Panel Voltage Regulator|Testing and Inspection|Page 5110 > < VDO Instrument Cluster|Page 5106