Accumulator HVAC: Description and Operation

-

The accumulator traps the mixture of refrigerant vapor and gas coming from the evaporator. While in the accumulator, the refrigerant vapor turns
to gas and, along with the refrigerant oil, is then taken in by the compressor.

-

An oil extraction passage is incorporated into the accumulator to ensure that refrigerant oil flowing with the refrigerant does not remain in the
accumulator.

-

Any moisture in the system is absorbed by the desiccant in the accumulator.

NOTE:  Do not remove caps -A- and -B- until ready to install the new accumulator. If caps are removed too soon, the desiccant becomes saturated
with moisture after a very short time, and the accumulator must be replaced.