Air Door Actuator / Motor: Testing and Inspection

NOTE:  Image shows the fresh air/recirculating flap vacuum motor with the heater box and evaporator housing assembly removed.

Located in passenger side, on right side of heater box.

-

Remove passenger side lower instrument panel cover.

-

Disconnect vacuum hose from vacuum motor.

-

Connect hand vacuum pump US 8026 to vacuum motor.

-

Create 300 mbar (20.7 in. Hg) of vacuum using pump and hold.

-

Fresh air/recirculating flap moves to stop (recirculating mode)

-

Vacuum must hold steady and not drop more than 1O% in two minutes.

-

Flap must remain in recirculating mode position 

If no:
-

Replace fresh air/recirculating flap vacuum motor.

NOTE:  Remove entire heater box and evaporator housing assembly to replace vacuum motor.