audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Vacuum Restrictor HVAC > < Charging Valve|Page 4436
Page 1
background image

Service Port HVAC: Description and Operation

High Pressure Service Valve

- Service valve connection (soldered to front of condenser)
- Schrader valve insert
- O-ring
- Cap with seal

-

Use only the specified R-134a quick coupling connectors when servicing the refrigerant system

-

Before removing the valve insert from the service valve, discharge A/C refrigerant system

-

Always reinstall cap -D- over service valve

NOTE:
-

Image shows the condenser and service valve of an Audi 100 model

-

Only a high pressure service valve is used for A/C system servicing. A low pressure service valve is not installed in the A/C system. Carry out all
A/C system service operations (i.e. discharging, evacuating, and charging) through the high pressure service valve only.

Vacuum Restrictor HVAC > < Charging Valve|Page 4436