Page 1
background image

Ignition Lock Cable: Adjustments

CAUTION:  The lock cable should always be adjusted with the cable in the installed position.

-

Loosen bolt (No. 1 in illustration)
-

Turn ignition switch to "on" position.

-

Rotate lock cable in installed position.

-

Insert 1.5 mm (0.059 in.) feeler gauge (A in illustration) between lock flap and locking pin.

-

Adjust lock cable in direction of arrow so that locking pin is pressed against feeler gauge.

-

In this position, tighten bolt (No. 1 in illustration).

-

Operate lock several times.

Clearance between locking pin and locking flap must be 1.2-1.7 mm (0.047-0.067 inch).

-

Move selector lever to "N" position.

-

Mount lock cable on selector lever housing.

It is important to make sure that the lock cable is laid in position free of sharp bends or kinks, and attached with a clip (arrow).

Perform Functional Check see Testing and Inspection