audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air/Fuel Mixture|Specifications|Page 1959 > < Air/Fuel Mixture|Specifications
Page 1
background image

Air/Fuel Mixture: Adjustments

AIR/FUEL MIXTURE CHECKING / ADJUSTING PROCEDURE 

NOTE: Air/fuel mixture is not adjustable on this vehicle but can be checked to verify the system operation.

PRE-CHECK REQUIREMENTS 

1.

Engine temperature at 185°F (85°C) minimum (operating temp.)

2.

Throttle valve in idle position

3.

Closed throttle position switch operating properly

4.

All electrical consumers turned OFF

5.

A/C turned OFF

6.

Fuel pressure gauge NOT connected

7.

Radiator fan MUST NOT run while taking measurements

8.

Crankcase breather connected

9.

NO diagnostic trouble codes stored in ECM fault memory

AIR/FUEL MIXTURE CHECKING PROCEDURE 

1.

Connect CO tester to right CO tap tube (right side exhaust manifold near Heated Oxygen Sensor) using adaptor 1363/3 and connecting hose
6006-0019 or equivalent.

2.

START engine and let idle, CO content should be:

Checking value 0.3 to 1.2% 

3.

Remove CO test probe from right CO tap tube, reinstall tube cap.

4.

Connect CO tester to left CO tap tube (left side exhaust manifold near Heated Oxygen Sensor) using adaptor 1363/3 and connecting hose
6006-0019 or equivalent.

5.

START engine and let idle, CO content should be:

Checking value 0.3 to 1.2% 

6.

Right side CO reading should be the same as Left side CO reading (only a slight difference is allowed).

7.

If CO Readings are NOT EQUAL 

^ Check BOTH Heated Oxygen Sensors for proper operation repair or replace as needed, refer to DIAGNOSIS, TESTING AND

INSPECTION PROCEDURES for procedure.

^ Ensure that all spark plugs are functioning properly repair or replace as needed.

NOTE: Failure of one spark plug increases CO content by approximately 1.5%.

^ Check and repair any vacuum leaks.

^ After repairs recall ECM fault memory, clear any Diagnostic Trouble Codes (refer to COMPUTERS AND CONTROL SYSTEMS for

procedure). Repeat entire MIXTURE CHECKING PROCEDURE above.

8.

If CO Readings are EQUAL but OUT OF SPECIFICATION 

^ Remove CO test probe from CO tap tube, reinstall tube cap.

^ Perform ENGINE BASIC ADJUSTMENT PROCEDURE below.

9.

If CO Readings are EQUAL and WITHIN SPECIFICATION 

^ NO adjustment needed, turn engine OFF.

^ Remove CO test probe from CO tap tube, reinstall tube cap.

ENGINE BASIC ADJUSTMENT PROCEDURE 

The MPI system is "adaptive" this means all engine adjustments are "learned" over a period of time. To return CO to proper levels the "learned" CO
adjustment stored in the MPI ECM must be erased and then "relearned". To erase these "learned" settings, battery power to the MPI ECM must be
disconnected. The ECM will then return to ENGINE BASIC ADJUSTMENT levels. When the engine is restarted the learning process begins again.

Air/Fuel Mixture|Specifications|Page 1959 > < Air/Fuel Mixture|Specifications