Removing, installing and checking gravity valve |
–
| To remove gravity valve -1-, release retaining tabs and pull valve upwards out of connection -3-. |
–
| Checking gravity valve: |
l
| Hold valve in a vertical position: it should be possible to blow through valve. |
l
| Tilt valve to 45°; it should not be possible to blow through valve. |
l
| Make sure O-ring -2- is not damaged. |
|
|
|