Connecting air conditioner service station on vehicles with a connection on the low and high-pressure end of the refrigerant circuit |
Connecting air conditioner service station for measuring and testing |
–
| Connect air conditioner service station to power supply. |
–
| Connect quick-release coupling adapters to the charging hoses of the air conditioner service station (handwheels not screwed in/hand shut-off valve not open). |
–
| Switch on the air conditioner service station and evacuate the charging hoses (only necessary if there is air in the charging hoses). |
–
| Switch off air conditioner service station. |
–
| Unscrew sealing caps from service connections (with valve). |
–
| Connect up the air conditioner service station via the service connections with quick-release coupling adapters to the vehicle refrigerant circuit. |
–
| Only screw in the handwheel of the quick-release coupling adapters to the extent required to reliably open the valves at the refrigerant circuit connection (observe pressure gauge, do not open valves further than necessary). |
–
| Perform planned tests and measurements. |
|
|
|