audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Restrictor > < Evaporator
Reservoir
Reservoir
   
To ensure that the air conditioner compressor draws in only gaseous refrigerant, the reservoir collects the mixture of vapour and gas coming from the evaporator. The vapour becomes gaseous refrigerant.
Refrigerant oil entrained in the circuit does not remain in the reservoir as an oil extraction hole is provided.
Any moisture ingressing into the refrigerant circuit during assembly is trapped by a filter (desiccant bag) in the reservoir.
Gaseous refrigerant with oil is drawn in by the air conditioner compressor.
  Note
t  Renew reservoir if refrigerant circuit has been open for a relatively long period and moisture has ingressed, or if renewal is stipulated due to a specific complaint → Chapter.
t  Do not remove the sealing plugs -A- and -B- until immediately prior to installation.
t  If the reservoir is not sealed, the desiccant bag soon becomes saturated with moisture and thus unusable.
t  When installing, observe arrow indicating direction of flow (if applicable).
  V87-1403

Restrictor > < Evaporator