| Remove the air conditioning system/Climatronic operating and display unit -E87- → Rep. Gr.87. |
–
| Reach through the opening and unplug the connector -1-. |
–
| Release the clips -arrows A- and slide the hazard warning light relay -J2--Item 2- in -direction of arrow B- out of the mount. |
Note Make use of the assembly tool -T10118- if the lower clip cannot be released. |
Install in reverse order, paying attention to the following: |
–
| Install the air conditioning system/Climatronic operating and display unit -E87- → Rep. Gr.87. |
|
|
|