audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Primary locking device with flat connector systems > < Primary locking device
Primary locking device with round connector systems
Primary locking device with round connector systems
Procedure
  Note
If housing securing elements (secondary locking devices) are fitted, they must be released or removed using the specified tool before releasing the contacts → Chapter.
   
–  Insert appropriate release tool for connector housing in release slot at connector housing.
–  Take hold of connector at wire and press it slightly into connector housing -left arrow-.
  Note
Pressing connector towards connector housing causes retaining tabs of connector to be lifted off housing shoulder, enabling them to be released with release tool.
–  At the same time, press release tool towards connector housing -right arrow- and pull released connector out of connector housing.
  N97-10286
–  After removing connector, pull release tool out of connector housing.
  N97-10287

Primary locking device with flat connector systems > < Primary locking device