audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Erasing fault memory > < Interrogating fault memory
Electrical system, Self-diagnosis
Parking aid (parking system) self-diagnosis
Parking aid fault table

Notes:

  • ◆ Listed in the following in ascending order of 5-digit fault codes are all the faults which can be detected by the parking aid and printed out on V.A.G 1551.
  • ◆ The fault code only appears on the printout.
  • ◆ Before replacing components found to be defective, use current flow diagram to check wiring and connectors to these components as well as earth connections.
  • ◆ On completion of repair work and system functional test, always interrogate fault memory again with fault reader V.A.G 1551 and erase it.
  • ◆ All static and sporadic faults are stored in the fault memory:
    A fault is recognised as being static if it is present for at least 2 seconds. If fault is then no longer present, it is stored as being sporadic and "/SP" appears on the right of the display.
  • ◆ After switching on ignition, all faults present are set to sporadic and only stored as being static if they are still present after checking.
  • ◆ Sporadic faults are erased if they do not re-occur in the course of 50 driving cycles (ignition on for at least 5 minutes, vehicle speed > 30 km/h).
  • ◆ When eliminating an open circuit in the event of a data bus fault, always remember to twist the two data wires of the corresponding bus system together to prevent electromagnetic interference.

Output on printer of
V.A.G 1551

Possible cause of trouble

Fault remedy

00532

Supply voltage

- Signal too low

- Open circuit in wiring or short circuit in power supply

- Use current flow diagram to perform fault-finding

00625

Speed signal

- Implausible signal

- Fault is set if vehicle-speed signal is implausible (e.g. 500 km/h); occurs, for example, in the event of loose contact in wiring

- Use current flow diagram to perform fault-finding

Output on printer of
V.A.G 1551

Possible cause of trouble

Fault remedy

01317

Control unit with display in dash panel insert -J285

- No communication

- Open circuit in wiring or short circuit
- Dash panel insert adaption not performed correctly

- Use current flow diagram to perform fault-finding
Eliminate open circuit in wiring
Select adaption channel 61 and enter correct adaption value

01336

Group convenience data bus

- Defective

- Short to positive/earth in both signal wires at one control unit in Group convenience data bus

- Use current flow diagram to perform fault-finding
Eliminate short circuit

Output on printer of
V.A.G 1551

Possible cause of trouble

Fault remedy

01543

Parking aid warning buzzer -H15

- Short to positive
- Open circuit/short to earth

- Open circuit in wiring or short circuit between -H15 and control unit
- Warning buzzer defective

- Use current flow diagram to perform fault-finding
Replace -H15

01545

RL parking aid sender -G203

- Short to positive
- Open circuit/short to earth
- Defective component
- Implausible signal

- Open circuit in wiring or short circuit between -G203 and control unit
- -G203 defective

- Use current flow diagram to perform fault-finding
Replace -G203

Output on printer of
V.A.G 1551

Possible cause of trouble

Fault remedy

01546

RL, ctr, parking aid sender -G204

- Short to positive
- Open circuit/short to earth
- Implausible signal

- Open circuit in wiring or short circuit between -G204 and control unit
- -G204 defective

- Use current flow diagram to perform fault-finding
Replace -G204

01547

RR, ctr, parking aid sender -G205

- Short to positive
- Open circuit/short to earth
- Implausible signal

- Open circuit in wiring or short circuit between -G205 and control unit
- -G205 defective

- Use current flow diagram to perform fault-finding
Replace -G205

Output on printer of
V.A.G 1551

Possible cause of trouble

Fault remedy

01548

RR parking aid sender -G206

- Short to positive
- Open circuit/short to earth
- Implausible signal

- Open circuit in wiring or short circuit between -G206 and control unit
- -G206 defective

- Use current flow diagram to perform fault-finding
Replace -G206

01549

Voltage supply for parking aid sender

- Short to earth

- Short to earth between parking aid sender and control unit

- Use current flow diagram to perform fault-finding

Output on printer of
V.A.G 1551

Possible cause of trouble

Fault remedy

01550

Reverse gear signal

- Implausible signal

- Short to earth between reversing light switch and parking aid control unit (reverse gear signal = 1 and vehicle speed > 100 km/h)

- Use current flow diagram to perform fault-finding
Eliminate short circuit

65535

Control unit defective

- Parking aid control unit -J446 defective

- Replace control unit

Erasing fault memory > < Interrogating fault memory