audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Recalls for Oxygen Sensor:|231013|Page 1078 > < Recalls for Oxygen Sensor:|231013|Page 1076
Page 2
background image

Criterion 8P

An ECM software update is required.

Criterion 02

A service regeneration must be performed. The rear oxygen sensor must be replaced.

Production Solution

For vehicles outside of the specified VIN range, the correct ECM software is already flashed.

Service

Tip: It is not necessary to receive a Repair Authorization to perform this or any other TDI clean diesel TSB.

Service regeneration and rear oxygen sensor replacement (criterion 02)

1. Ensure engine is at operating temperature and fuel level is above 1/4 tank.

2. Using the VAS 5052 (or equivalent), select GFF >> 01-Engine Electronics, functions >> 01 - Diesel Particle Filter, emergency regeneration (RG.26).
Select the option for a stationary regeneration and follow the steps given by the test tool to burn off any residual condensation in the exhaust system.

3. Once the regeneration function is complete, the exhaust system will be very hot. Begin work on criterion 01 procedure to allow the exhaust system to
cool before completing criterion 02 below.

Software update with SVM code 23F2A001 (criterion 8P)

1. Follow all instructions in the attached TSB 2011732 00 Software Version Management (SVM), operating instructions.

2. Update the ECM using the SVM action code as listed in the table below, if necessary.

Continuation of service regeneration and rear oxygen sensor replacement (criterion 02)

1. Replace rear oxygen sensor (bank 1, sensor 2 G130). Refer to directions in ElsaWeb >> Repair Manual >> Engine >> Fuel Injection and Glow Plug
>> 23 Diesel Fuel Injection >> Removal and Installation >> Oxygen Sensor after Three Way Catalytic Converter.

2. Return parts removed during this RVU.

a. The SAGA system will generate a parts return sheet and barcode for this RVU.

b. Include all parts removed during this RVU. Include all pages of the part return sheets with the parts shipment.

c. Return only parts removed during this RVU. Do not include any other items you need to send to the Warranty Parts Return Center with your
shipment.

Tip: Any items shipped that do not relate to this RVU will not be acknowledged or returned.

USA Dealers

An electronic FedEx shipping label will be generated in the Warranty Parts Shipping Portal (WPSP) for RVU 23F2 parts that are to be returned under
this RVU.

Ship to:

Recalls for Oxygen Sensor:|231013|Page 1078 > < Recalls for Oxygen Sensor:|231013|Page 1076