audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 7335 > < With Generic Scan Tool|Page 7333
Page 6
background image

-

Switch off ignition.

-

Connect Test Box V.A.G 1598/42 to wiring harness with adapter cable V.A.G 1598/39- 2. Clamp test box Ground (GND) clip to battery negative
terminal. The procedure will indicate whether the engine control module is to be connected to the test box or not.

CAUTION:  To avoid damaging electronic components, set measuring range before connecting test leads and observe all test
requirements.

-

Check the following wire connection for open circuit and short circuit to Ground (GND) and B+:

Harness connector Terminal

V.A.G 1598/42 Bushing 

- 1

- 40

-

Repair wiring open circuit or short circuit according to wiring diagram.

-

Install Leak Detection Pump (LDP) V144.

If no malfunction is found, but leak diagnosis pump is not functional during output diagnostic test mode:

-

Replace engine control module (ECM) and observe procedures for after re-connecting engine control module (ECM).

With Generic Scan Tool|Page 7335 > < With Generic Scan Tool|Page 7333