A3 L4-2.0L Turbo (BPY) (2006)
-
Pre-adjust bypass flap - 1 - via knurled nut - arrow - so flap can still just be turned by hand.
-
Install lock nut hand tight.
-
Connect hand vacuum pump (VAS 6213), turbocharger tester (V.A.G 1397A) to connection II and pressure regulator valve (VAS 6342) as
depicted in the illustration.