audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor and Heater before Catalytic Converter|Page 6082 > < Heated Oxygen Sensor (HO2S) G39|Page 6079
Page 1
background image

Oxygen Sensor: Service and Repair
Heated Oxygen Sensor and Heater before Catalytic Converter

Heated Oxygen Sensor and Heater before Catalytic Converter

Special tools, testers and auxiliary items required

‹› Ring spanner 7-piece set for oxygen sensor (3337 )

Removing the oxygen sensor

-

Remove engine cover => [ Air Filter and Engine Cover ] See: Fuel Delivery and Air Induction/Air Cleaner Housing/Service and Repair/Air Filter
and Engine Cover.

-

Disconnect electrical harness connector - 1 - of the Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor (O2S) Heater (Z19).

-

Remove oxygen sensor - arrow - using tool from Ring Spanner 7 piece set (3337).

Installing the oxygen sensor

When installing, note the following:

‹› New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.

‹› For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with sensor slots. Hot bolt paste

‹› Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided. 

Heated Oxygen Sensor and Heater before Catalytic Converter|Page 6082 > < Heated Oxygen Sensor (HO2S) G39|Page 6079