Oxygen Sensor: Service and Repair
Heated Oxygen Sensor and Heater before Catalytic Converter

Heated Oxygen Sensor and Heater before Catalytic Converter

Special tools, testers and auxiliary items required

‹› Ring spanner 7-piece set for oxygen sensor (3337 )

Removing the oxygen sensor

-

Remove engine cover => [ Air Filter and Engine Cover ] See: Engine, Cooling and Exhaust/Engine/Tune-up and Engine Performance Checks/Air
Cleaner Housing/Service and Repair/Air Filter and Engine Cover.

-

Disconnect electrical harness connector - 1 - of the Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor (O2S) Heater (Z19).

-

Remove oxygen sensor - arrow - using tool from Ring Spanner 7 piece set (3337).

Installing the oxygen sensor

When installing, note the following:

‹› New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.

‹› For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with sensor slots. Hot bolt paste

‹› Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided. 