A3 L4-2.0L Turbo (BPY) (2006)
-
At the same time, push release tool in direction of terminal housing and pull released contact out of terminal housing -arrow-.
-
Remove release tool after removing contact from housing.
Asymmetrical:
-
Guide release tool (which fits terminal housing) into release channel on terminal housing.
-
Grasp contact at wire and push gently into terminal housing -arrow-.
NOTE: By pushing contact in direction of terminal housing, contact retaining tabs are lifted off the housing shoulder and can be released using
release tool.
-
At the same time, push release tool in the direction of terminal housing and pull released contact out of terminal housing -arrow-.
-
Remove the release tool after removing the contact from the housing.