A3 L4-2.0L Turbo (BPY) (2006)
Wiring Harness: Removal and Replacement
Primary Connector With Special Connector Systems
Primary Connector With Special Connector Systems
Procedure
NOTE: If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts.
Fasten contacts:
-
Guide release tool (that fits terminal housing) into release channel on terminal housing -arrow-.
-
Grasp contact at wire and push gently into terminal housing.
NOTE: By pushing contact in direction of terminal housing, contact retaining tabs are lifted off the housing shoulder and can be released using
release tool.
-
At the same time, push release tool in direction of terminal housing and pull released contact out of terminal housing -arrow-.
-
Remove release tool after removing contact from housing.
GT 150/280 contacts:
-
Guide release tool (which fits terminal housing) under retaining tab into terminal housing.
-
Push tool into terminal housing until it stops -arrow -.