audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Condenser|Page 5638 > < Condenser|Page 5636
Page 2
background image

-

Check the refrigerant circuit pressure using a pressure gauge from the A/C Service Station A/C System with Refrigerant R134a

CAUTION!
Only remove Seeger ring - arrow
 - when pressure in refrigerant circuit is the same or less than the ambient pressure.

-

Remove the Seeger ring - arrow - and pull the cap -  1 - off the condenser - 2 - using an M12. screw.

-

Remove the dryer cartridge using a commercially available pick-up tool - in direction of arrow - from the condenser.

-

Make a welding wire (dia. 2 mm) to the following dimensions. 

a

380 mm

b

maximum 7 mm

c

maximum 6 mm

Hook the welding wire to the strainer exactly as illustrated to prevent damaging the condenser.